Motor casings require a 1-minute hydrostatic test post-machining: 1 MPa for Class I/IIA/IIB, 1.5 MPa for IIC. Qualification allows ≤1 drop/10 sec. Handle carefully, protect explosion-proof surfaces, clean and dry thoroughly, apply rust-preventive oil to mating and threaded surfaces before assembly.